ECO ETS – Assembly Buddy SETTINGS DRIVE PARAMETERS (PARAMETER) Parameter Description Setting range Default Vo Vc TOEx TKey TDelay FDelay TLock FLock FSlam FWind Fo Fc Foh Fch Ao Rod Invers dAxis Fos Velocity open (velocity open) Velocity close (velocity close) 0…14 (5…50 °/s) 0…14 (5…0 °/s) Hold open time opening element inside / outside (time hold opening element inside/outside) 0…60 s Hold open time Key (time hold opening element Key) Start-up delay (time delay lock) Relief force when unlocking (force delay), only works if TDelay is >0. Door hold-up time (time press close) Pressing force while locking (force lock), only works when TLock is >0. Slam function (force slam) Obstacle detection optimised for external doors. (force wind) Opening force (force open) Closing force (force close) Hold open force (force open hold) 0…180 s 0,0…4,0 s 0,0…7,0 A 0,0…4,0 s 0,0…7,0 A 0…10 OFF OPEN CLOSE BOTH 0…9 0…9 0…9 Locking force (force close hold) automatically sets FLock and FDelay if they are 0 0,0…3,5 A Opening angle of the door (angle open) If the opening angle is changed in the OPEN mode, the operating mode must be changed to HAND to close the door. Linkage types (Rod) Inverse-Application: In case of power failure / error, the door leaf is opened from any position by spring force (if not locked). Position of the motor plug is reversed to the standard drive. The electric lock / holding magnet must be connected in reverse to the standard drive (see wiring diagram E4-0141-713). Distance between door hinge rotation axis and the drives mounting level (distance Axis). dAxis is a guide value. Depending on the mounting situation, dAxis must be adapted accordingly. Standard arm pressing Sliding rail pulling Sliding rail pushing Leaf mounting pushing Without linkage pushing Without linkage pulling Limitation of the opening force. Must not be increased in Germany! 20…(190 °) Rod dep. STD - PH SLI - PL SLI - PH WIN - PH DIR - PH DIR - PL OFF ON -8…+25 cm Rod dep. 5…14 A 6 4 3 s 5 s 0,2 s OFF 0,5 s 2,0 A OFF OFF 4 4 0 0 95 ° * STD - PH * OFF * 0 / +8 cm Rod dep. * 5 A * Note: A new set-up process (Teach) is required. 26